Rear housing 1
±Warning: This product contains high voltage and a high-vacuum picture tube. To prevent serious injury, review CRT safety in Bulletins/Safety and read the safety guidelines at the beginning of this chapter.
Use a flat-blade screwdriver to press in on one of the side tabs on the anode cap cover. Lift up that side. Repeat for the other side.
2 Tilt up the anode cap cover and release it from the two back slots on the top EMI panel.
Using the CRT discharge tool (Apple part number 076-0381 ), connect the clip to the metal CRT frame and insert the needle underneath the anode cap to discharge the CRT.
4 Remove the anode cap from the anode aperture.
5 For working inside the monitor with the power off, establish an ongoing ground by using a cable with alligator clips at both ends. Connect one end to the anode aperture, and connect the other end to the metal CRT frame.
6 With the CRT discharged and the ongoing ground in place, wear a grounding wriststrap to prevent equipment damage from static electricity.